Search Swinburne Research Bank
Home
List of Titles
Theoretical and experimental evaluation of microstreaming created by a single microbubble: application to sonoporation
List of Titles
Theoretical and experimental evaluation of microstreaming created by a single microbubble: application to sonoporation
Please use this identifier to cite or link to this item: http://hdl.handle.net/1959.3/240028
- Title
- Theoretical and experimental evaluation of microstreaming created by a single microbubble: application to sonoporation
- Author(s)
- Novell, Anthony; Collis, James; Doinikov, Alexander A.; Ooi, Andrew; Manasseh, Richard; Bouakaz, Ayache
- Abstract
- It is hypothesized that microstreaming might play a role in the sonoporation process, inducing shear stresses which create tension and stretching over the cell membrane and thus lead to its transient permeabilization. In this study, the results of microscopic particle-image velocimetry (PIV) for large bubbles are presented and compared to those obtained using a numerical model. Air bubbles were created in a water solution and then attached to a wall. For each bubble, the microstreaming was measured over a plane located at a distance of 50 μm from the bubble wall. Bubbles were excited using a single element transducer at 28 kHz and 7 kPa. The acoustic microstreaming generated by the air bubble was calculated for the same excitation signal by using a theoretical model based on an analytical solution of the time-averaged Navier-Stokes equation. This approach was also applied to estimate the flow around an encapsulated contrast microbubble using an excitation signal centered at 2.87 MHz with a pressure amplitude of 50 kPa. PIV measurements show that a maximal average velocity of 0.25 mm/s occurs near the bubble resonant size (244 μm diameter bubble). For this bubble, the shear stress is also maximal. Theoretical data are in good qualitative agreement with PIV measurements. Using the contrast agent microbubble model, a maximal flow velocity and shear stress of 4 mm/s and 19 Pa respectively are obtained for a 2.5 μm diameter bubble. The shear stresses are much higher than those produced by normal blood flow (0.5 - 2 Pa). These results suggest that bubbles are capable of exerting significant shear stresses on the cell membrane, affecting likely the sonoporation process.
- Publication type
- Conference paper
- Research centre
- Swinburne University of Technology. Faculty of Engineering and Industrial Sciences
- Source
- Proceedings of the 2011 IEEE International Ultrasonics Symposium (IUS 2011), Orlando, Florida, United States, 18-21 October 2011, pp. 1482-1485
- Publication year
- 2011
- Keyword(s)
- Bubbles; Microstreaming; Particle-image velocimetry; PIV; Shear stress; Sonoporation; Velocity
- Publisher
- IEEE
- ISSN
- 1948-5719 (series ISSN)
- ISBN
- 9781457712531, 1457712539
- Publisher URL
- http://dx.doi.org/10.1109/ULTSYM.2011.0367
- Copyright
- Copyright © 2011 IEEE.
- Peer reviewed